ns=2;s=DEPRAG Smart/Devices/DEPRAG/AST/ActiveDevices/0/SystemOverview/ToolData/ToolDataItemsCount
Requests the number of items of tool data.
In addition to the parameters already explained, the following variables must be created / transferred for the implementation in TwinCAT 3:
VAR
bAstToolDataItemsCount : BOOL;
outputAstToolDataItemsCount : ST_Int32OutputData;
hrAstToolDataItemsCount : HRESULT;
fbAst : FB_AST;
END_VAR
hrAstToolDataItemsCount := fbAst.ToolDataItemsCount(
bExecute := bAstToolDataItemsCount,
ConnectionHandle := depragSmartConnection.ConnectionHandle,
sDeviceId := '0',
OutputData => outputAstToolDataItemsCount);
IF hrAstToolDataItemsCount <> S_FALSE THEN
bAstToolDataItemsCount := FALSE;
END_IF
For examples and explanations regarding the calls of nodes via Siemens TIA Portal please refer to the sub-menu "Siemens TIA Portal" in section "Getting Started".